2025-04-28

In our daily lives, gas provides us with great convenience, but gas leaks can also lead to serious safety accidents.


In recent years, the Shield Household Combustible Gas Detector has become an increasingly popular choice as an important safeguard for home gas safety. To facilitate daily use for all users, we’ve compiled this Household Combustible Gas Detector User Guide to provide detailed instructions on how to use the Shield gas detector.

 

Product Selection and Compatibility

 

As a professional gas detector manufacturer, Shield offers over 20 models in its household combustible gas detector series. These primarily detect gases such as natural gas, liquefied petroleum gas (LPG), and carbon monoxide (CO).

 

Before purchasing, please confirm the type of gas used in your household and the specific gas you wish to detect. Our professional pre-sales engineers will help you select the appropriate model.

 

Installation and Usage Precautions

  • The detector should be installed indoors, where gas or vapors are likely to accumulate.
  • Refer to the installation diagram:
  • If the target gas is lighterthan air, install the detector above the source.
  • If the target gas is heavierthan air, install the detector below the source.
  • The mounting plate should be firmly and evenly fixed as shown in the diagram.
    • Do notinstall the detector near exhaust fans, windows, or doors where air flows heavily.
    • Avoid placing the detector directly above stoves, range hoods, or areas exposed to heat, steam, or oil fumes.
    • There should be no obstructionsbetween the detector and the gas appliances. Do not install it inside cabinets or enclosed spaces.
    • Do notinstall the detector in areas where power is cut off at night.
    • In newly renovated homes, install the detector only after paint, welding, or other work is completed, and ensure proper ventilation after installation.
    • Do notclean the detector with alcohol or spray insecticides near it, as this may affect sensor performance.
    • Do notsmoke near the detector.
    • When the detector indicates that the sensor has reached the end of its service life, replace it promptly.
    • To ensure detection accuracy, the detector should be stored properly according to the specified storage environment after leaving the factory. For optimal product quality, storage time should not exceed 6 months.

 

In our daily lives, gas provides us with great convenience, but gas leaks can also lead to serious safety accidents.08.jpg

 

Product Operation – Powering On

 

Before powering on, check whether the power supply and connection lines are functioning properly.
Once powered, the detector will perform a self-check. The indicator lights will flash in a cycle for approximately 10 seconds, followed by a single beep, then the detector will enter its normal working mode.

 

Note: The detector will not trigger an alarm during the self-check phase!

 

In our daily lives, gas provides us with great convenience, but gas leaks can also lead to serious safety accidents

(Illustration: 6200 series normal power-on state)

 

Product Operation – Calibration / Historical Records

Before calibration, ensure the detector is in a clean air environment and has been powered on and functioning normally for at least 30 minutes.


Press the self-test button to enter manual self-test mode. Then, press and hold the button again until the normal (green) and service life (yellow) indicators flash alternately. The device is now in calibration mode.

 

Introduce the target gas at a flow rate of 0.3–0.5 m/s (or place the detector in a calibration environment with the target gas).


Wait until the alarm indicator flashes rapidly for 60 seconds, then press the self-test button again. When the alarm light stays on and the buzzer sounds, the gas calibration is complete.

 

Note:

  • Before testing and verification, the product must be powered on in clean air for at least 48 hoursto age.
  • If the detector has been in use or in storage for more than 12 months, it should be powered on in clean air for at least 72 hours, then recalibrated before testing.
  • Installation, debugging, and calibration should be performed by trained professionals.
    To ensure accuracy, calibration should be done once a year, and every 6 monthsin special environments.

 

History Records

Record Type

Maximum Number of Records Stored

Alarm Record of Detector

200

Alarm Recovery Record of Detector

200

Fault Record of Detector

100

Fault Recovery Record of Detector

100

Power Loss Record of Detector

50

Power On Record of Detector

50

Gas Sensor Failure Record

1

 

Indicator Lights and Key Description:

  1. Normal status

Working Status

Indicator Light Status

Buzzer

Normal

Green Flashing

Silent

Key Description: Under normal condition, press the “self-test” key to carry out sound and light self-test, and linkage output.

 

In our daily lives, gas provides us with great convenience, but gas leaks can also lead to serious safety accidents

(6200 series normal state)

 

  1. Fault state

Working Status

Indicator Light Status

Buzzer

Fault

Yellow light steady on

intermittent beeping

Key Description: Press the “Self-check” key in the alarm state to muffle the alarm.

 

In our daily lives, gas provides us with great convenience, but gas leaks can also lead to serious safety accidents

(6200 series fault status)

 

  1. Alarm status

Working Status

Indicator Light Status

Buzzer

Alarm

Red light steady on

urgent beeping

Key Description: Press the “Self-test” key under the fault condition to muffle the fault.

 

In our daily lives, gas provides us with great convenience, but gas leaks can also lead to serious safety accidents

(6200 Series Alarm Status)

 

Working Status

Indicator Light Status

Buzzer

End of Life

Yellow flashing

Silent

Power-on Self-Check

Power-on self-check, indicator light flashes in a loop, enters normal working status after 10s.

Beeps once when self-check is complete, enters normal working status.

Manual Self-Check

Instruction Press the self-test button, the light cycle blinks for 10s, and the process starts the linkage output. After completing the self-test, it enters the normal working state

Continuous beeping during manual self-check.

Household combustible gas alarm handling

 

Emergency Response

 

When the household combustible gas detector emits a sharp alarm sound, first of all, keep calm. Immediately turn off the gas valve in your home to stop the gas from continuing to leak; quickly open doors and windows to enhance indoor ventilation and reduce the concentration of gas in the room. During the whole process, do not switch on or off any electrical equipment, including lights, exhaust fans, etc., because the sparks generated by electrical switches may ignite the leaking gas and cause an explosion.

 

Examine the source of leakage

 

Under the condition of ensuring safety, carefully check the gas equipment, such as the connections of gas stoves and gas pipes for breakage and looseness, and whether the valves of liquefied petroleum gas tanks are closed tightly. If you can find and solve minor leaks on your own, such as tightening loose pipe connections and leaving them to ventilate for a period of time, the household combustible gas detector alarm will usually stop. However, if you can not determine the cause of leakage or leakage is more serious, you should immediately evacuate the scene and call the gas company's customer service number or alarm number, waiting for professionals to come to deal with.

 

Reset Operation

 

After the gas leakage problem is solved and the room is well ventilated, and the gas concentration is reduced to a safe range, the alarm sound of the household combustible gas detector will stop automatically. If the alarm sound persists, you can press the reset button on the alarm to return it to the normal monitoring state. However, please note that the reset operation must be carried out after confirming that the gas leakage problem has been completely solved, otherwise the alarm may be triggered again by the residual gas.

 