China JYFJS-011 Aluminum Alloy Electromagnetic Shut-off Valve Suppliers | Emergency Gas Safety Solutions Factory
Working Principle and Structural Diagram
- Operation Mode: This valve is a normally open shut-off valve with a holding control mode. It remains open without power during normal operation and can automatically close upon receiving a shut-off signal.
- Manual Reset & Self-Holding: After closing, it can be manually opened and will automatically close again upon receiving another shut-off signal.
- Emergency Response: When a leakage accident occurs, the alarm system sounds an alert, instantly providing a DC pulse voltage to the solenoid valve. The coil is energized, driving the valve to quickly close, cutting off the gas source and entering a self-locking state.
- Pulse Drive Mechanism: When a gas leak occurs, the alarm's capacitor continuously releases a 3-second DC pulse voltage, energizing the coil, closing the valve to cut off the gas supply, and entering a self-locking state.
- Force Interaction: The interaction of instantaneous electromagnetic force of the coil, permanent magnetic force, and spring force is used to achieve pulse drive, automatic valve closing, and manual valve opening self-holding functions.
Component Specifications
| Serial Number | Area Name |
|---|---|
| 1 | Valve body |
| 2 | Diaphragm |
| 3 | Valve cover |
| 4 | Spring |
| 5 | Actuator |
| 6 | Reset Device |
| 7 | Dust cover |
| 8 | Moving iron core |
| 9 | Sealing ring |
Frequently Asked Questions (FAQ)
What is the default state of the valve during normal operation?
The valve is normally open and operates in a holding control mode, remaining open without power during normal operations.
How does the valve close automatically during a gas leak?
Upon detecting a leak, the alarm system triggers and provides a DC pulse voltage to the solenoid valve. The coil is energized, driving the valve to close rapidly and cut off the gas supply.
Does the valve reopen automatically after the signal stops?
No, once the valve closes, it enters a self-locking state. It must be manually opened to reset and resume operation.
What type of electrical signal triggers the valve closure?
The valve is closed by a continuous 3-second DC pulse voltage released from the alarm's capacitor to energize the coil.
What forces are used to operate the valve?
The system achieves automatic closing, pulse drive, and manual opening self-holding functions through the interaction of instantaneous electromagnetic force, permanent magnetic force, and spring force.
What are the primary internal components of this valve?
Key components include the valve body, diaphragm, valve cover, spring, actuator, reset device, dust cover, moving iron core, and sealing ring.